Part Number Hot Search : 
P3100 80286 P3100 DWR2G 80C196JR CY3686 AT45D R1005
Product Description
Full Text Search
 

To Download W005M04 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 MCC
TM
Micro Commercial Components
omponents 20736 Marilla Street Chatsworth !"# $
% !"#
W005M THRU W10M
1.5 Amp Single Phase Bridge Rectifier 50 to 1000 Volts
WOM
A
Features
* * * * * Low Profile Package Any Mounting Position Silver Plated Copper Leads Surge Overload Rating Of 50 Amps UL Recognized File # E165989
Maximum Ratings
* * Operating Temperature: -55C to +125C Storage Temperature: -55C to +150C MCC Catalog Number W005M W01M W02M W04M W06M W08M W10M Device Marking Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V Maximum RMS Voltage 35V 70V 140V 280V 420V 560V 700V Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000v
B
W005M W01M W02M W04M W06M W08M W10M
D
C
F AC
Electrical Characteristics @ 25C Unless Otherwise Specified
Average Forward Current Peak Forward Surge Current Maximum Forward Voltage Drop Per Element IF(AV) IFSM 1.5A 50A TJ = 25C 8.3ms, half sine
E + AC
-
E
VF
1.0V
IFM = 1.5A; TJ = 25C*
DIMENSIONS DIM A B C D E F INCHES MIN ------1.000 1.098 .180 .028 MAX .358 .225 ----.220 .032 MM MIN ----------25.40 27.90 4.60 0.71 MAX 9.10 5.70 ----5.60 0.81 NOTE
Maximum DC Reverse Current At IR 10A TJ = 25C Rated DC Blocking 1mA TJ = 100C Voltage *Pulse test: Pulse width 300 sec, Duty cycle 1%
Revision: 5
www.mccsemi.com
2004/10/13
MCC
TM
W005M thru W10M
Figure 1 Typical Forward Characteristics 100 60 40 20 10 6 4 2 Amps 1 .6 .4 .2 .1 .06 .04 .02 .01 .2 .4 .6 .8 1.0 1.2 1.4 TJ=25C 10 6 4 2 1 .6 .4 .2 Amps .1 .06 .04 .02 .01 .006 .004 .002 .001 20 40 60
Micro Commercial Components
Figure 2 Typical Reverse Characteristics
TJ=25C
80 Volts
100
120
140
Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts
Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts
Figure 3 Forward Derating Curve 1.8 1.5
Figure 4 Peak Forward Surge Current 60 50 40
1.2
30
Amps 0.9 0.6 0.3
Amps
20 10 0
Single Phase, Half Wave 60Hz Resistive or Inductive Load 25 50 75 100 125 150
1
2
4
6
8 10 Cycles
20
40 00
60 80 100
0
0
Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles
Average Forward Rectified Current - Amperes versus Case Temperature - C
Revision: 5
www.mccsemi.com
2004/10/13


▲Up To Search▲   

 
Price & Availability of W005M04

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X